objectid |
Automatically generated unique identifier |
Numerical |
pid_global |
Greenspace unique ID identifier |
Numerical |
area_m2 |
Area of the greenspace in m² |
Numerical |
avbl_ar_20 |
Available area assuming that 20% can be used in m² |
Numerical |
avbl_ar_40 |
Available area assuming that 40% can be used in m² |
Numerical |
avbl_ar_60 |
Available area assuming that 60% can be used in m² |
Numerical |
aa_40_cat |
Classification of available area at 40% of the total area based on equal count intervals: HIGH >= 816, MEDIUM 199 – 816, LOW < 199 based on 3 equal count classes.
|
Textural |
stp_slp |
Flag to indicate the greenspace contains land which has a slope of 18% or over |
Textural |
lhd_suit |
Linear heat density (LHD) suitability. If the PID falls within LHD band 4000, suitability is "Potentially Suitable LHD"; If the PID falls within LHD band 8000, suitability is "Suitable LHD"; If the PID falls within LHD band 16000, suitability is "Highly Suitable LHD" |
Textural |
lhd_p_suit |
Linear heat density (LHD) suitability based on public demand. If the PID falls within LHD band 4000, suitability is "Suitable LHD |
Textural |
gshp_20_p |
Ground source heat pump peak potential, based on available area being at 20% of the total area (measured in MW)
|
Numerical |
gshp_20_a |
Ground source heat pump annual potential, based on available area being at 20% of the total area (measured in MWh/annum)
|
Numerical |
gshp_40_p |
Ground source heat pump peak potential, based on available area being at 40% of the total area (measured in MW) |
Numerical |
gshp_40_a |
Ground source heat pump annual potential, based on available areabeing at 40% of the total area (measured in MWh/annum)
|
Numerical |
gshp_60_p |
Ground source heat pump peak potential, based on available area being at 60% of the total area (measured in MW) |
Numerical |
gshp_60_a |
Ground source heat pump annual potential, based on available area being at 60% of the total area (measured in MWh/annum) |
Numerical |
gshp_40a_c |
Classification of GSHP annual potential based on available area being at 40% of the total area – HIGH > 137090, MEDIUM 33421 – 137090, LOW < 33421 based on 3 equal count classes.
|
Numerical |
gshp_s_v |
Ground source heat pump site viability (Yes or No) |
Textural |
d_50_p |
Total demand from public building heat map points within 50m (measured in MWh/annum) |
Numerical |
c_d_50_p |
Count of public building heat map points within 50m |
Numerical |
m_d_50_p |
Maximum demand value from public building heat map points within 50m (measured in MWh/annum) |
Textural |
m_d_50_p_u |
UPRN of public building within the highest demand value within 50m |
Textural |
m_d_50_p_c |
Classification of "Max_Demand_Within_50m_Public": <= 19681: 'low' <= 37846: 'medium'
> 37846: 'high'
|
Textural |
met_d_50_p |
Check to see if supply (taken as column "GSHP_40_Perc_Annual") covers the public demand within 50m (taken as column "Total_Demand_Within_50m_Public") |
Textural |
d_500_p |
Total demand from public building heat map points within 500m (measured in MWh/annum) |
Numerical |
c_d_500_p |
Count of public building heat map points within 500m |
Numerical |
d_500 |
Total demand from heat map points within 500m (measured in MWh/annum) |
Numerical |
g_m_d_500 |
Check to see if supply (taken as column "GSHP_40_Perc_Annual") covers the demand within 500m (taken as column "Total_Demand_Within_500m") |
Textural |
g_m_d_500p |
Check to see if supply (taken as column "GSHP_40_Perc_Annual") covers the public demand within 500m (taken as column "Total_Demand_Within_500m_Public")
|
Textural |
dhn_500 |
Check to see if a District Heating network is within 500m |
Numerical |
f_p_c_500 |
Count of properties in fuel poverty within 500m |
Numerical |
ha_c_500 |
Count of properties in fuel poverty within 500m |
Numerical |
f_p_p_500 |
Percentage of Home Analytics properties in fuel poverty within 500m |
Numerical |
f_p_p_cat |
Category (High/Medium/Low) based on percentage of Home Analytics properties in fuel poverty within 500m (LOW < 0.17; MEDIUM 0.17 - 0.29; HIGH > 0.29) based on equal count classes
|
Textural |
gg_c_500 |
Count of Home Analytics properties on the gas grid within 500m |
Numerical |
g_of_c_500 |
Count of Home Analytics properties off the gas grid within 500m |
Numerical |
g_on_p_500 |
Percentage of Home Analytics properties on the gas grid within 500m |
Numerical |
g_of_p_cat |
Category (High/Medium/Low) based on percentage of Home Analytics properties on the gas grid within 500m (LOW < 0.909; MEDIUM 0.909 - 0.984; HIGH > 0.984) based on equal count classes
|
Textural |
gg_check |
Check to see if the PID intersects with the off gas grid areas defined in shape
file used in Phase 1 of ParkPower project
|
Textural |
swb_area |
Combined area of all static waterbodies within 100m (measured in m²) |
Numerical |
nswb_area |
Combined area of all non-static waterbodies within 100m (measured in m²) |
Numerical |
wshp_area |
Combined area of all waterbodies (measured in m²) |
Numerical |
wshp_suit |
Water source Heat Pump suitability categories based on "Area_WSHP_m2" = 0: 'low'
<= 1649: 'medium' > 1649: 'high'
|
Textural |
local_auth |
Name of the local authority which the greenspace falls in. If the greenspace falls in two or more local authorities, then it takes the name of the local authority where the largest area falls |
Textural |
settlement |
Settlement code of the settlement which the greenspace falls in. If the greenspace falls in two or more settlements, then it takes the name of the settlement where the largest area
falls |
Textural |
partners |
Name of the Partner area which the greenspace falls in. If the greenspace falls in two or more Partner area, then it takes the name of the Partner area where the largest area falls |
Textural |
easting |
Easting coordinate in British National Grid |
Numerical |
northing |
Northing coordinate in British National Grid |
Numerical |
x_wgs1984 |
X coordinate in WGS 1984 |
Numerical |
y_wgs1984 |
Y coordinate in WGS 1984 |
Numerical |
shape_leng |
Automatically generated column indicating length of perimeter (measured in metres) |
Numerical |
shape_area |
Automatically generated column indicating area (measured in m²) |
Numerical |
gs_s_i |
Classification based on Linear heat
density (demand for heat) and output
potential (supply of heat):
(1) VERY HIGH = LHD_Suitability is
"Highly Suitable LHD" and
GSHP_40_A is in highest decile (>=1063 MWh)
(2) HIGH = LHD_Suitability is "Highly
Suitable LHD" and GSHP_40_A in 2
nd
highest decile (340 – 1063 MWh).
(3) MEDIUM = LHD_Suitability is
"Highly Suitable LHD" and
GSHP_40_A < 340 MWh OR
LHD_Suitability is "Suitable LHD" and
GSHP_40_A > 340 MWh OR
LHD_Suitability is "Potentially Suitable
LHD" and GSHP_40_A >= 1063 MWh.
(4) LOW = all others |
Textural |